[Model Supported] All the DHO4000 series oscilloscopes [Latest Revision Date] 2024/03/27 [Updated Contents] 00.02.13 2024/03/27 - Fixed the problem of deleting files when copying the same files. - Requirements for optimizing the total time for oscilloscope delivery, configuration, and reading. - Fixed the problem of crash when LAN is not connected and click Apply. - Fixed the problem that after passing the test screenshot, it cannot be stopped. - After fixing the default, *IDN? cannot read the project version number. - The problem of not closing the project version number lxi/identification. - Fixed the issue of statistics not being reset when moving the measurement cursor. - Fixed the problem that the measurement value of the moving cursor area is not updated after STOP. - Fixed the problem of occasional no waveform when booting. - Fixed the issue of the waveform disappearing in small gears after a pause. - Implementation of USB external keyboard requirements. - Fixed the problem of obtaining Math waveform error. - Fixed vertical scaling mask error by testing. - Fixed SPI timeout triggering problem, also for four-channel mode. - Modify the problem that ultraLab cannot connect to the server after shutting down and restarting. - When the Zoom function is turned on, the cursor adjustment area is not limited to the Zoom window. - Modify the offset range below 50 ohm and 500uV/div to solve the flip problem. - Fixed the problem of failure to modify the settings of measurement source B. - Fixed the problem of window transparency and failure to load the last value. - Fixed the problem of error in saving screen waveform to csv and SCPI command to obtain waveform in Math filter operation. - Fixed the problem of crosstalk caused by adjusting vertical offset. - One-click to open the measurement items required by the user and realize the functional requirements of the trigger source tracking channel. - Error displayed when modifying the measurement cursor for multi-source measurement. - Fix the problem of IIC SCL threshold and SDA threshold random reset&trigger level line random jumping caused by probe ratio at 10X gear. 00.02.12 2023/10/18 - Fixed the problem of CAN decoding result misalignment when there is an error frame - Fixed the problem of wrong value in measurement when switching frequency meter source - Optimize customer experience of frequency meter statistics function - Fixed the issue where the median boundary value measurement results and cursor indication are incorrect when the display type is percentage. 00.02.11 2023/08/17 - PassFail function optimization - Ref function optimization - Read screen data, fix the abnormal number of return values - Waveform distortion before triggering with large time base - CAN trigger related issues resolved - Fixed the wrong format of saved memory bin wave file - Fix low storage depth, after ZOOM is turned on, the square wave will be stabbed - Fix the data abnormality at the end of the high-resolution mode waveform - Fixed the inconsistent behavior of XY window switch operation - Fix the invalid initialization of webcontrol network settings - Fix Pass/fail cannot be terminated - Fixed the problem that SCPI could not get the measurement value - Fixed the problem of loss of test mask in special cases 00.02.07 2023/04/29 - Custom external attenuation ratio - Add the merge display function of MATH window and simulation window - Add the window shrink function through Pass-Fail - Cursor module zero stagnation function, to solve the problem that the cursor is difficult to capture 0V first - Add a toggle switch for merging screens, which can display cursors in each split screen and synchronize the cursors - The measurement function adds [cursor area] measurement function requirements - Fixed crash issue in German mode - Pause to keep the afterglow display after turning on the waveform hold - Fixed the truncation problem of enlarged waveform after stoping - Fixed the problem that the adjustment trigger point could not be adjusted back to the middle of the screen after moving to the right for more than -50S under a large time base - Fixed Crash problem when restarting with probe 00.02.04 2022/12/14 -Released the production version